2-Pole Miniature Circuit Breaker 20A
Two-pole 20A miniature circuit breaker for low-voltage electrical protection. Designed for use in distribution boards. Suitable for residential and commercial installations
Availability
- Riyadh · Saudi Arabia
- Dubai · United Arab Emirates
- Doha · Qatar
- Kuwait City · Kuwait
Description
Two-pole circuit protection device intended to interrupt electrical circuits under overcurrent or fault conditions
Applications
- Building distribution boards
- residential electrical systems
- offices and commercial installations
Specifications
Available on request: Voltage, Breaking capacity, Trip curve, Frequency. Tell us the configuration you need and we will confirm these in writing: Get Quote
Choosing and specifying this item
Two-pole 20A ways are most often found on single-phase motor-driven plant — split-system condensing units, small pumps, booster sets, compressors. Loads that start hard and cycle often.
Starting current chooses the curve
A motor draws several times its running current for a brief period, and a hermetic compressor restarting against residual head pressure draws more again. Take the locked-rotor or starting current from the equipment nameplate and send that figure with the enquiry so the trip curve can be matched to it. Rating up to stop start-up tripping is the wrong fix: it leaves the cable under-protected against the sustained overload it actually needs protection from.
This device is not motor protection
An MCB protects circuit conductors against overload and short circuit. It does not replace a motor thermal overload, an internal thermal cut-out, or the protection built into packaged plant. Establish what the equipment already carries before assuming the breaker covers the motor.
Confirm on the enquiry
Rated voltage for the intended line-and-neutral or line-to-line duty, breaking capacity for the fault level at that board, frequency suitability, and two free adjacent ways. If plant trips repeatedly on hot afternoons, treat it as an ambient and load question before treating it as a breaker fault.
See what else is available in Miniature Circuit Breakers — Additional Ratings, Electrical. See also: Containment: Trays, Trunking and Conduit in Hot Climates.
Frequently asked questions
Will a two-pole 20A hold a split-system compressor on start-up?
Does this breaker protect the motor itself?
Our pump breaker only trips in the afternoon in summer. Is the breaker faulty?
Related Products
More in Electrical
- Electrical Wires & Cables
- Miniature Circuit Breakers
- Residual Current Circuit Breakers
- Moulded Case Circuit Breakers
- Distribution Boards & Electrical Panels
- Switches, Sockets & Wiring Accessories
- Building Wires & Cables
- Consumer Distribution Boards
- Metal Distribution Boards & Electrical Enclosures
- Switches & Sockets — Additional Products
- Multicore Copper Cables
- General
- Electrical Accessories & Control Equipment